How does a fire backup generator meet the requirements of a registered fire engineer?
Diesel Generator | Diesel Generator Price / 2018-04-16
How does a fire backup generator meet the requirements of a registered fire engineer?
1. It should be arranged on the ground floor or the ground floor or on the ground floor. It should not be placed on the upper floor, the lower floor or the adjacent floor of a crowded place. Diesel equipment or diesel tanks that need to be installed in the building should have a flash point of less than 60°.
2. The fireproof partition wall with a fire-resistance limit of not less than 2.00h and the non-combustible floor slab with 1.50h shall be separated from other parts. The door shall be Class A fire doors.
3. When the oil room is set in the machine room, the total storage capacity shall not be greater than 1m3. The oil storage room shall be partitioned between the fireproof partition wall and the generator with a fire-resistance limit of not less than 3.00h; it is necessary to open the door on the fireproof partition wall. , Class A fire doors should be installed.
4. Fire alarms should be set up.
5. Fire extinguishing facilities that are compatible with diesel generator capacity and construction scale should be set. When automatic sprinkler systems are installed in other parts of the building, an automatic sprinkler system should be installed in the engine room.
6. The diesel generator installed in the building, the fuel supply pipeline shall meet the following requirements:
1) Automatic and manual shut-off valves shall be provided on the pipelines before entering the building and within the equipment room.
2) The oil tank in the oil storage room shall be closed and a ventilation pipe leading to the outside shall be provided. The ventilation pipe shall be provided with a breathing valve with a flame arrester. The lower part of the tank shall be provided with facilities to prevent the oil from flowing.
3) The laying of gas supply pipelines shall comply with the provisions of the current national standard, the "Guidelines for Urban Gas Design" GB50028.
When the regional power supply conditions cannot meet the power supply reliability requirements of the first-level fire load and the second-level load, it is necessary to consider setting up a fire-fighting standby diesel generator set to meet the power supply requirements. However, not all the sets can be used as fire-fighting standby diesel generator sets. .
The self-contained emergency generator set shall be equipped with a quick automatic start and automatic power switching device, and shall have three consecutive self-starting functions. For a type of high-rise building, the time for the self-start switching does not exceed 30s; for other buildings, manual starting devices may also be used when it is difficult to use automatic starting. The unit should generally use electric starting and should not start with compressed air. The total number of generator sets should not exceed 2 sets, and the stand-alone capacity is generally 800KW or less. The requirements for the self-contained power generation equipment (self-contained emergency generator set) of the high-rise building's fire-fighting power supply are: (1) A type of high-rise building-owned generator set shall be provided with an automatic starting device and be capable of supplying power within 30 seconds; (2) When a self-provided generator set is used for a Class II high-rise building, manual starting devices may be used when it is difficult to use automatic starting.
The diesel generator set used as a standby for fire protection has high requirements for quality. We use good service for the unit to repay customers. Welcome everyone to buy.
Quick start, easy operation and maintenance.
Most of the enterprises and institutions like banks, supermarkets with large passenger flow, and e-commerce companies have diesel generators. In the event of a sudden power outage, diesel generators come in handy at this time. Start the unit, as long as the supply of diesel is guaranteed, the unit can basically be used as a standby power supply, and the maintenance of the diesel engine is also very convenient.
With less investment, the cost of raw materials is low. Can effectively save money.
Compared with some other alternative power supply equipment, diesel generator sets are relatively inexpensive and their consumption of raw materials (diesel) is relatively low.
Fire-fighting standby diesel generators have stable performance and strong adaptability to the environment. The diesel engine itself has a low travel rate and is relatively durable.
Previous:How to carry out regular maintenance and maintenance of diesel generator sets?
Automatic glass cutting line include automatic glass loading machine,automatic Glass Cutting Machine and automatic glass breaking machine.
Our Automatic Glass cutting line adopt Japan YASKAWA servo system and LNC controller. The main feature is operate conveniently, wide application, high cutting speed, higher precise cutting size, fast, stable, and accurate start and stop. This machine units have fully automatic operation for glass taking ,sending, cutting and breaking with high production efficiency, low labor intensity, which is suitable for mass production.
Automatic Glass Cutting Line,Low-E Insulating Glass Production Line,Advanced Insulating Glass Production Machine,Ce &Iso-9001 Approved Insulating Glass Machine
JINAN WEILI MACHINE CO LTD , https://www.wlglassmachines.com